Product Overview
The 91-0775C-02 Replacement Charger for the Simco-Ion Model 775 Periodic Verification System (775PVS) is a replacement unit designed to provide polarized high voltage to the 775PVS plate assembly. The charger acts as the interruptible power source in the verification kit and is used to charge the plate so that measurements and verification of ionizer function can be performed.Function and Construction
The charger is powered by a 9V alkaline battery and provides a nominal output voltage of 1300 VDC ±20% for each polarity. The output current is limited to <1 μA. The unit has two stainless steel contact plates; which plate is grounded determines the output polarity. An LED indicator light shows red when the pushbutton is activated.Documentation
View manufacturer's datasheetTypical Applications
The application of the 91-0775C-02 is described in the 775PVS datasheet: when the plate unit is connected to the field meter and the charger is used, the complete system can be used to verify ionizer operation and check ion balance and discharge times. The charger provides the necessary polarized voltage to the plate as part of these verification measurements.Specifications
- Product information / order code: 91-0775C-02
- Power supply: 9V alkaline battery
- Output voltage: 1300 VDC ±20% per polarity
- Output current: limited to <1 μA
- Contact plates: two stainless steel (SST)
- Polarity selection: depends on which contact plate is grounded
- LED indicator: red when pushbutton is activated
- Dimensions: 4.28"L x 2.41"W x 0.86"D (10.9 x 6.12 x 2.18 cm)
- Weight: 0.25 lb (0.113 kg) with battery